item No.
Setting the printing area for folio paper
U035
Description
Changes the printing area for copying on folio paper.
Purpose
To prevent cropped images on the trailing edge or left/right side of copy paper by setting the actual printing
area for folio paper.
Setting
1. Press the start key.
2. Select the item to be set.
3. Change the setting using the +/- keys.
Display
LENGTH DATA
WIDTH DATA
4. Press the start key. The value is set.
Completion
Press the stop key. The screen for selecting a maintenance item No. is displayed.
Checking the operation of the fan motors
U037
Description
Drives the fan motors.
Description
To check the operation of the fan motors.
Method
1. Press the start key.
2. Select the motor to be operated.
3. Press the start key. The operation starts.
Display
Fixing Fan
Developing Fan
LSU Rear Fan
Low Power Source Fan
Mid Transfer Fan
Power Source Fan
Conveying Fan
CONT Fan
POLYGON Motor Fan
Rotary Guide Fan
Loop Sensor Fan
Mid Transfer Belt Fan
Eject Fan
ISU Fan
ALL
4. To stop operation, press the stop key.
Completion
Press the stop key. The screen for selecting a maintenance item No. is displayed.
1-3-28
Description
Setting
Length
Width
Operation
Fuser fan motor (FUFM) is turned on.
Developing fan motor 1, 2 (DEVFM1, 2) are turned on.
Developing fan motor 5 (DEVFM5) is turned on.
Power source fan motor 2 (PSFM2) is turned on.
Transfer fan motor 1 (TRFM1) is turned on.
Power source fan motor 1 (PSFM1) is turned on.
Paper conveying fan motor 1, 2 (PCFM1, 2) are turned on.
Container fan motor (CFM) is turned on.
LSU fan motor (LSUFM) is turned on.
Rotary fan motor (RFM) is turned on.
Loop fan motor (LFM) is turned on.
Transfer fan motor 2, 3 (TRFM2, 3) is turned on.
Eject fan motor (EFM) is turned on.
Scanner fan motor (SFM) is turned on.
All fan motor are turned on.
Setting range
330 to 356 mm
200 to 220 mm
Initial setting
330
210