U140 Displaying Developing Bias - Kyocera TASKalfa 250ci Service Manual

Hide thumbs Also See for TASKalfa 250ci:
Table of Contents

Advertisement

Maintenance
item No.
Displaying developing bias
U140
Description
Displays various developing bias value.
Purpose
To check the developing bias value.
Method
1. Press the start key.
2. Select the item to be set or displayed.
Display
Dev Roll2 DC
Dev Roll2 AC
Dev Roll1 Normal
Roll1 Normal Int
Roll1 ON/OFF KC
DEV Roll Freq
DEV Roll Duty
Dev Roll2 DC Interval
Dev Roll1 Freq Interval
Dev Roll1 Duty Interval
Setting: [Dev Roll2 DC]
1. Select the item to be set.
2. Change the value using the +/- or numeric keys.
Display
Dev Roll2 DC (C)
Dev Roll2 DC (M)
Dev Roll2 DC (Y)
Dev Roll2 DC (K)
Dev Roll2 DC (BW) Developing sleeve roller DC bias in black/white
*1: 40/40, 50/40 ppm model *2: 25/25, 30/30 ppm model
3. Press the start key. The value is set.
Setting: [Dev Roll2 AC]
1. Select the item to be set.
2. Change the value using the +/- or numeric keys.
Display
Dev Roll2 AC (C)
Dev Roll2 AC (M)
Dev Roll2 AC (Y)
Dev Roll2 AC (K)
Dev Roll2 AC (BW) Developing sleeve roller AC bias in black/white
3. Press the start key. The value is set.
Description
Description
Developing sleeve roller DC bias
Developing sleeve roller AC bias
Developing magnet roller bias
Developing magnet roller paper interval bias
Developing magnet roller ON/OFF timing
Developing magnet roller frequency
Developing magnet roller duty
Developing sleeve roller paper interval DC bias
Developing magnet roller paper interval frequency
Developing magnet roller paper interval duty
Description
Developing sleeve roller DC bias for cyan
Developing sleeve roller DC bias for magenta
Developing sleeve roller DC bias for yellow
Developing sleeve roller DC bias for black
mode
Description
Developing sleeve roller AC bias for cyan
Developing sleeve roller AC bias for magenta
Developing sleeve roller AC bias for yellow
Developing sleeve roller AC bias for black
mode
2JZ/2JX/2JV/2H7-1
Setting
Initial
range
setting
0 to 255
93
/80
*1
*2
0 to 255
93
/80
*1
*2
0 to 255
93
/80
*1
*2
0 to 255
93
/80
*1
*2
0 to 255
101
/87
*1
*2
Setting
Initial
range
setting
0 to 255
174
0 to 255
174
0 to 255
174
0 to 255
174
0 to 255
174
1-3-69