Detaching And Refitting The Mp Forwarding, Mp Paper Feed And Mp Separation Pulleys - Kyocera TASKalfa 250ci Service Manual

Hide thumbs Also See for TASKalfa 250ci:
Table of Contents

Advertisement

2JZ/2JX/2JV/2H7

(3) Detaching and refitting the MP forwarding, MP paper feed and MP separation pulleys

Follow the procedure below to clean or replace the MP forwarding, MP paper feed and MP separation pulleys.
Procedure
Removing the MP forwarding and MP feed pulleys
1. Remove the MP unit (see page 1-5-6).
2. Remove the lever and spring from the MP
unit.
3. Release the MP solenoid lever in the direc-
tion of the arrow.
4. Remove three stop rings.
5. Slide the joint and remove two bushes.
Remove the pulley unit from the MP unit.
1-5-8
Stop ring
MP solenoid
lever
Lever
Figure 1-5-12
Bush
MP unit
Figure 1-5-13
Spring
MP unit
Stop rings
Pulley unit
Bush
Joint