11. When the cylinders have stopped filling pull the faceplate relief valves until product comes out. Do
not bleed air too fast or product will foam in the freeze cylinders.
Relief
valve
13. Repeat steps 10 and 11 for the other freeze cylinders.
14. Press BACK twice to go to the Main menu.
15. Press ON, after 5 seconds the compressor will start and the beater bars will rotate counterclockwise.
Wait 10 – 15 minutes and test the product.
NOTE: Make sure the controller is programmed before pressing ON.
16. Install the second side panel, splash panel, drip tray, and top cover.
© 2003-2014, Cornelius Inc.
Pinnacle 2 and 4 Flavor Service Manual