Cornelius FCB - 2 Flavor Service Manual page 35

Fcb pinnacle
Table of Contents

Advertisement

Menu 16 - BRIX
Cylinder
Number
Selection
Pointer
The BRIX menu allows the activation of syrup and water solenoids, and blendonator pump motor for a
selected cylinder.
PRESSURE SWITCH AND
WATER REGULATOR
WATER
FLOW REGULATOR
AND SOLENOID VALVE
SYRUP
SOLD-OUT SWITCH
1.
Make sure the status of all cylinders is OFF on the display.
2.
Turn product supply valve to the 90 degree (OFF) position for the barrel you are using. It is
recommended to close both valves to be sure the correct valve is chosen.
3.
Press MENU. Then press UP repeatedly until BRIX is displayed. Press GO and select cylinder you
wish to Brix. NOTE: Pressing CANCEL will stop the process.
4.
Locate the appropriate (correct barrel) sample tube and hold a cup under it.
NOTE: If Product Sample Valve is located in a different position then FIGURE 25 see the
schematics in Appendix A for the two alternate constructions (section 1 and 2) and their
respective Brixing instructions.
5.
Open the valve at the end of the sample tube. Press GO and wait 3-5 seconds. The product pump
will pump product for approximately 3 seconds. After sample is dispensed Press Go twice more to
dispense product two more times. Discard these first three samples.
© 2003-2014, Cornelius Inc.
FIGURE 24
SINGLE
CHECK
VALVE
PRODUCT PUMP
(SYRUP AND WATER
ARE MIXED)
PRODUCT SAMPLE VALVE
FIGURE 25
Pinnacle 2 and 4 Flavor Service Manual
COOLING COIL
DOUBLE
CHECK
VALVE
WATER ICE BATH
- 31 -
BRIX
Status
FREEZE
CYLINDER
PRODUCT SHUTOFF
VALVE
BLENDONATOR
Publication Number: 560007298SER