Menu 17 - MANUAL DEFRST
Cylinder
Number
Selection
Pointer
The MANUAL DEFRST menu allows the activation of 2 minute manual defrost mode for a selected cylin-
der. This defrost cycle can begin with the cylinder in any mode (ON, OFF, Motor) and will return the cylin-
der to that same mode. Manual defrost can be activated on only 1 cylinder associated with a compressor
at a time.
The description of the button 2 will change based on the status of the selected cylinder. When not in
defrost, button 2 will read DFRST. When in defrost, button 2 will read CANCL.
Pressing DFRST will begin a manual defrost on the selected cylinder, and pressing CANCL will end the
manual defrost on the selected cylinder.
MANUAL DEFRST Menu Button Descriptions:
#1 - BACK . . . . . . . go back to the previous menu
#2 - DRFST . . . . . . begin manual defrost on selected cylinder (defrost will last approx 2 minutes)
#4 - UP . . . . . . . . . . move selection pointer up
#5 - DOWN. . . . . . . move selection pointer down
© 2003-2014, Cornelius Inc.
Pinnacle 2 and 4 Flavor Service Manual
FIGURE 27
- 33 -
Defrost
Status