Cornelius FCB - 2 Flavor Service Manual page 28

Fcb pinnacle
Table of Contents

Advertisement

Menu 9 - VISC DISPLAY (Actual Cylinder Viscosity)
Cylinder
Numbers
This menu displays the actual viscosity value for each cylinder. The smaller the number the lower the vis-
cosity (thinner product).
VISC DISPLAY Menu Button Descriptions:
#1 - BACK . . . . . . . go back to the previous menu
The table below identifies the maximum and minimum viscosity values for specific viscosity settings. For
example, with a viscosity setting of 2, the system calls for refrigeration when the viscosity drops below 43.
Refrigeration continues until the viscosity reaches 60 when leveling begins.
NOTE: There is a 2 minute timer to prevent the compressor from short cycling. This timer is can-
celed out by a Blendonator actuation.
Viscosity Setting
1
2
3
4
5
6
7
8
9
© 2003-2014, Cornelius Inc.
FIGURE 17
Maximum Viscosity
Minimum Viscosity
Value
50
60
70
80
90
100
110
120
130
- 24 -
Pinnacle 2 and 4 Flavor Service Manual
Actual Viscosity
Reading
Value
36
43
58
68
78
86
96
106
116
Publication Number: 560007298SER