3.3 SOFTWARE DIP SWITCH COMMAND

This section describes the new software commands to set the DSW 2 and DSW 3 when DSW 2-8 is set to
ON. According to the command language, the software DIP switch commands are separated between SATO
and SZPL modes.

3.3.1 DSW 2 Setting Command (SBPL command)

Hex code
ESC
<1B>
Default Value
,0,0,0,0,0,0,0
FUNCTION
FORMAT
PARAMETER
EXAMPLE
SPECIAL NOTES
GZ4e Series Operator Manual
DSW 2 SETTING
16
To set the DSW-2 settings by software command
<ESC> + DW2,a,b,c,d,e,f,g
a
[DSW 2-1]
b
[DSW 2-2]
c
[DSW 2-3]
d
[DSW 2-4]
e
[DSW 2-5]
f
[DSW 2-6]
g
[DSW 2-7]
<ESC>A
<ESC>DW2,0,1,0,0,0,0,0
<ESC>Z
Above code snippets will set the DSW 2-2 to ON and so, the printer sensor type will be set
at I-mark when the printer restarts.
1 This command is valid only when DSW 2-8 is ON.
2 The parameters of this command cannot be omissible. The command will be ignored if
the parameters are missing or incorrect.
3 The LCD menu and DSW settings will become effective after the printer restarts.
4 Users can send this command to printer in Normal mode and Flash Download mode.
5 If software DSW 2-4 is switch to ON, it can be switch to OFF from HEXDUMP MODE
LCD under Service Mode.
6 When software DSW 2-4 is ON, press LINE and FEED buttons while power-up will get
the printer into the Factory Mode directly. The software DSW 2-4 will be switch to OFF
automatically.
7 Selection from HEXDUMP MODE LCD under Service Mode will change software DSW
2-4 accordingly.
8 Printer factory clear and default settings will not reset the software DSW 2 settings.
9 This command cannot be used to set the DSW 2-8.
10 When hardware DSW 2-8 is switch to ON from OFF position, software DSW-2 command
setting will be automatically set to default values (software DSW2 default setting: DSW 2-
5 OFF (1-item), DSW 2-8 ON (Software DSW) and other DSW OFF).
Section 3: Configuration and Operation
DW2
<44>
<57>
<32>
16
16
16
= 0 : OFF / 1 : ON
= 0 : OFF / 1 : ON
= 0 : OFF / 1 : ON
= 0 : OFF / 1 : ON
= 0 : OFF / 1 : ON
= 0 : OFF / 1 : ON
= 0 : OFF / 1 : ON
ESC + DW2
Parameter
,a,b,c,d,e,f,g
[Transfer / Direct]
[Gap / I-mark]
[Head check Disable / Enable]
[Hex Dump & Factory Mode Disable /Enable]
[1-item / Multi-Buffer]
[Download Disable / Enable]
[Standard / Non Standard]
Page 3-7