HP R12000 User Manual page 91

Directflow ups
Hide thumbs Also See for R12000:
Table of Contents

Advertisement

Trap code
Alarm name
Low battery
27
Battery bad
28
REPO initiated
29
DB missing
30
BM missing
31
Battery low shutdown
32
Overload shutdown
33
Wiring fault
34
Attach > 2 BP
35
Not same BP type
36
BP not compatible
37
BM not compatible
38
BP cable missing
39
BP disconnected
40
BP comm loss
41
Internal comm loss
42
On manual bypass
43
Self-diagnosis fault
44
PWR not compatible
45
ACC active
46
Manual power on
47
Manual power off
48
Remote power on
49
Remote power off
50
Testing battery
51
Battery is aging
52
BP not ready 1
53
BP not ready 2
54
Alarm description
Battery time remaining is lower than the battery low
warning level defined for the UPS.
A battery inside the battery pack is aging or
abnormal.
The external REPO contacts on the power unit have
been activated.
The distribution box (input/output power module)
was not connected to the power unit or the signal
was lost.
A battery module is missing.
Shut down the power unit due to low batteries.
Shut down the power unit due to overload.
The input wiring of the 3-phase power unit is not
correct.
More than two battery packs are connected to the
same power unit.
Two different battery pack types are connected to
the same power unit.
The firmware version of a battery pack is not
compatible with the power unit.
The firmware version of a battery module is not
compatible with the battery pack.
The signal cable between the power unit and the
battery pack is not connected.
The DC power cable is missing or the battery pack
breaker is not in the on position.
The communication between the battery pack and
the power unit is lost.
The power unit MCU lost communication with the
power unit DSP.
Turn the switch on the back of the power unit and
the load is supplied by utility directly.
The inverter voltage cannot be boosted to the
default level.
The firmware version of the power DSP is not
compatible with the system MCU.
ACC circuit is currently active.
Press and hold the Enter button to turn on the power
unit.
Press and hold the ESC button to turn off the power
unit.
Use this command to turn on the power unit.
Use this command to turn off the power unit.
The batteries are being tested.
The battery is aging and cannot support sufficient
battery runtime.
The 1U battery pack is performing self-diagnosis
and the battery modules are not ready.
The 1U battery pack is being reconfigured and the
battery modules are not ready.
Alarm type
Critical
Critical
Critical
Critical
Critical
Critical
Critical
Critical
Warning
Warning
Warning
Warning
Warning
Warning
Warning
Warning
Warning
Warning
Warning
Informative
Informative
Informative
Informative
Informative
Informative
Informative
Informative
Informative
Troubleshooting 91