5. INSTALLATION AND INITIAL SETTINGS
How to ground the FI-70
1. Fabricate a grounding cable (IV-1.25sq., local supply) with a close-end terminator
(local supply).
2. Connect the close-end terminator to the rear of the FI-70, as indicated in the figure
on the previous page.
3. Connect the loose end of the grounding cable to the ship's ground.
5.2.2

How to connect to the Wind Transducers FI-5001/L

The IF-NMEAFI Analog Data Converter is required when connecting the Wind
Transducer FI-5001 or FI-5001L, in order to convert the analog data from the sensor
to CAN bus/NMEA2000 format data. When connecting the FI-70 to the FI-5001 or
FI-5001L, use the terminal box included with the FI-5001 or FI-5001L.
For details on installation of the IF-NMEAFI and FI-5001 or FI-5001L, refer to the
Installation Manual (IMC-72661) or Installation Guide (C72-01403).
Wind Transducer FI-5001 or FI-5001L
External sensor connection cable
IF-NMEAFI Analog Data Converter
1. Referring to the figures below, fabricate the external sensor connection cable and
FI-50-SENSOR cable.
FI-50-SENSOR cable (FI-5001/L)
Cut off the connector to
fabricate the cable.
Braided
shield wire
Outer sheath
Outer sheath
5-6
FI-50-SENSOR cable
External sensor connection cable (IF-NMEAFI)
Cut unused wires to a
5
suitable length, then isolate
them with vinyl tape.
40
Dimensions shown in millimeters (mm).
Terminal box
FI-70
Outer sheath
Outer sheath
5
40