Furuno FICE-100 Installation Manual

Furuno FICE-100 Installation Manual

Ice radar, oil radar
Hide thumbs Also See for FICE-100:

Advertisement

Quick Links

Furuno Finland Oy
INSTALLATION MANUAL
FURUNO FINLAND
ICE RADAR FICE-100
FURUNO FINLAND
OIL RADAR FOIL-200
1
Page
www.furuno.fi

Advertisement

Table of Contents
loading

Summary of Contents for Furuno FICE-100

  • Page 1 INSTALLATION MANUAL FURUNO FINLAND ICE RADAR FICE-100 FURUNO FINLAND OIL RADAR FOIL-200 Furuno Finland Oy Page www.furuno.fi...
  • Page 2: Table Of Contents

    Contents 1. SPECIFICATIONS ........................4 2. CABLING AND CONNECTORS ....................5 2.1 Connectors on EC-3000 processor ................. 5 2.2 Sensor Data Input ....................... 6 2.2.1. Introduction ........................6 2.2.2 Serial Interface sensor information ................. 6 2.2.3 LAN Interface for sensor information ................7 2.3 Connectors on ScanStreamer ..................
  • Page 3 Version E, 07 JUN 2019 Page...
  • Page 4: Specifications

    1. SPECIFICATIONS Interconnection diagram: List of Equipment (Standard): Name Type Ice/Oil Radar processor unit EC-3000 Power cable Control Panel RCU-030 USB cable Radar video digitizer ScanStreamer DNP2012001 or ScanStreamer MK II Power cable 2.5 m List of Equipment (Optional): Name Type Signal cable (for FAR-2xx7) FICE-110...
  • Page 5: Cabling And Connectors

    2. CABLING AND CONNECTORS 2.1 Connectors on EC-3000 processor Below you can find connectors on EC-3000 processor back panel. Power input LAN2 connection RCU-030 LAN1 connection Video adapter for VDU to ScanStreamer to Sensors Control Unit Page...
  • Page 6: Sensor Data Input

    LAN interface. Only one interface can be used. 2.2.2 Serial Interface sensor information Following sentences can be received by FICE-100/FOIL-200: HDT, THS, GLL, GGA, VTG, ZDA, VBW, VHW, TTM, VDM, MTW Below you can find connectors for serial line sensor data inside EC-3000 processor. Connector J3 can be used for Gyro signal input (38400 bps).
  • Page 7: Lan Interface For Sensor Information

    Connectors J5-J10 are for IEC61162-1 Pin No Signal In/Out Description TDx-A No connection TDx-B No connection RDx-H IEC61162-2 RDx-C IEC61162-2 ground x= 3, 4, 5, 6, 7, 8 2.2.3 LAN Interface for sensor information Configuration of sensor receiving from MC-3000/HUB-100 can be done in “sensor.conf” file. You need to configure LAN1 into the same network as MC-3000/HUB-100.
  • Page 8: Connectors On Scanstreamer

     ScanStreamer DNP2016009  Check which one you have in your system. A ScanStreamer receives raw radar video from Furuno navigation radar, FAR-2xx7, FAR-2xx8, FAR-15x8 or FAR-3000. Following information is received from Furuno navigation radar. It digitizes analogue video and send it to EC-3000 through LAN: ...
  • Page 9 Connector J4 Bearing pulse Head line Connector J4 Pin No Signal Description ARP IN Head line ground Sync in No connection No connection ACP IN Bearing pulse Ground SYNC OUT No connection No connection No connection Page...
  • Page 10: Scanstreamer Dnp2016009

    2.3.2 ScanStreamer DNP2016009 Below is shown connectors on DNP2016009: Video Bearing pulse Trigger LAN connection Power input Head line to EC-3000 Oil radar/Ice radar (EC-3000) processor receives digitized radar video through LAN connection. Connector J3 Bearing pulse Head line Connector J3 Pin No Signal Description...
  • Page 11: Connector On Rpu-013 Of Far-2Xx7

    2.4 Connector on RPU-013 of FAR-2xx7 Connect cable to SLAVE 1 connector (J617) Connect FICE-110 cable to SLAVE 1 connector 2.4 Connector on RPU-024 of FAR-15x8 Connect cable to SLAVE 1 connector (J611) Connect FICE-110 cable to SLAVE 1 connector Page...
  • Page 12: Connectors On Up-Mast Unit Of Far-2Xx8/Far-3000

    2.5 Connectors on up-mast unit of FAR-2xx8/FAR-3000 Connect FICE-110 cable to TB 803 (trigger, bearing pulse and head line) and to TB804 (radar video) as shown below. Radar video cable connected to TB 804 connector (TO SLAVE DISPLAY WAGO connector connected to TB 803 connector Page...
  • Page 13: Configuration Of Display Resolution

    3. CONFIGURATION OF DISPLAY RESOLUTION When booting up the system it is automatically detecting display connected to system. For some cases system fails to detect correctly connected display and you need to manually enter display resolution and dimensions of monitor. To configure manually display resolution, precede as follows: 1.
  • Page 14 3. Enter width in millimeters 4. Enter height in millimeters 5. Check that you have correct values and confirm by selecting Yes. Page...
  • Page 15: Configuration Of Parameters

    4. CONFIGURATION OF PARAMETERS 4.1 Vessel dimensions and antenna offsets Sensor and conning positions on ship are in “vessel.config” file, which must be edited at installation time. No. Description Function Power up Ice/Oil radar Startup Ice/Oil radar Open login screen Press Alt+x to open console Edit vessel.config file type: nano vessel.config [enter]...
  • Page 16: Adjustment Of Video Level

    5 ADJUSTMENT OF VIDEO LEVEL 5.1 Video level and ADC Gain When installation of FICE-100/FOIL-200 is done, you have to check that video level is correctly set. FICE-100/FOIL-200 radar uses raw radar video from navigation radar to make ICE/Oil radar image on FICE-100/FOIL-200 screen.
  • Page 17: How To Activate Radar Video Adjustment Mode

    Photos above: Video level offset is adjusted. You can see in scope display that video is readable during antenna sweep in whole range. 5.2 How to activate radar video adjustment mode You can activate FICE- 100/FOIL-200 video adjustment mode: 1. Click Alt+x keys together to get console on screen.
  • Page 18: How To Adjust Video Level Offset

    5.3 How to adjust video level offset Adjustment range of Video Offset: ScanStreamer DNP2012003: -1.00 - 1.00 ScanStreamer DNP2016001: 0 - 255 To adjust video level offset: Before video level adjustment: 1. Click Radar test button, then click Show/Hide. 2. Video signal adjustment window appears, click Radar test button to open menu.
  • Page 19: How To Adjust Adc Gain

    5.4 How to adjust ADC gain Adjustment range of ADC Gain: ScanStreamer DNP2012003: 0 - 6 ScanStreamer DNP2016001: 0 - 255 Before gain adjustment: To adjust video level: 1. Click Radar test button to open menu. 2. Move cursor in ADC Gain button and adjust ADC Gain by scrolling thumb wheel.
  • Page 20: How To Adjust Trigger Delay

    5.5 How to adjust Trigger delay You may need to adjust trigger delay on FICE-100/FOIL-200. This is very much depending on cable length between navigation radar and ScanStreamer. Measure distance of echo on Navigation radar. Measure the same echo on FICE-100/FOIL-200, if there is difference in distance you can use Trigger delay to adjust echoes on FICE-100/FOIL-200 display.
  • Page 21: Performance Test For Navigation Radar

    6. PERFORMANCE TEST FOR NAVIGATION RADAR 6.1 FAR-2xx7 FAR-2xx7 is used as normal navigation radar. To verify performance of radar, see installation manual of FAR-2xx7. Following should be proceeded: • “Tune initialize” • Check TX time of magnetron • Use “Performance monitor” to check gain. Performance monitor is an option. If not available, check TX time of magnetron.
  • Page 22: Troubleshooting

    7. TROUBLESHOOTING 7.1. No data from serial data sensors If heading or position is missing, you can do following things: 1. Check that data is sent by the sensor(s). 2. Check that cabling is correctly done and connectors properly fixed. To check configuration of COM –ports: A) Sensor traffic Click Alt+x together to open console...
  • Page 23: Interconnection Diagram

    8. INTERCONNECTION DIAGRAM Page...
  • Page 24 Page...

This manual is also suitable for:

Foil-200

Table of Contents