Section 4
Setting Method
Return to factory default setting
Factory default setting
Initial setting
Types of code, which is possible to read EAN/UPC, CODE39, NW-7, STF, ITF
Number of reading digits
Detail condition CODE39 detail setting Invalid C/D of CODE39
Reading
condition
Communication
condition
LED illumination
Buzzer sound
Buzzer sound volume
Buzzer frequency
External trigger signal
READ OK/NG signal output
READ OK/NG signal output system
V500-R521B2/C2
58
User's Manual
Menu sheet
Item
No designated number of digits
Transfer C/D of CODE39
Transfer ST/SP of CODE39
NW-7 detail setting
Invalid C/D of NW-7
Transfer C/D of NW-7
Transfer ST/SP of NW-7 (abcd/abcd)
ITF/STF detail setting
Invalid C/D of ITF/STF
Transfer C/D of ITF/STF
Reading system
Trigger reading
Reading operation
Single reading
Reading valid time
Trigger + 2 sec.
Number of reading
Twice (Verification: once)
coincidence
Communication speed 9600 bps
Data length
8-bit
Parity
None
Stop bit length
1-bit
Header
None
Footer
CR
Transfer number of
Not transferred
digits
RS/CS control
None
CS waiting time
Infinity
Communication
No protocol system
protocol
Process when reading
No process (Nothing is transferred)
is NG
LED illumination time after decoding is 200 ms.
Buzzer sound duration after decoding is 200 ms. W5
Max.
3 kHz, 2 kHz
Negative logic (L active)
Output
Trigger synchronous system, positive logic
(H active)
Command
UA
Setting content
Corresponding
command
J1+R4+B2+B3
+R7+R8
H0
C0
C2
D1
F7
F5
F4
G0
G2
S8
S0
Y2
X1
K6
L1
L2
L5
1Y
1Z+1C
2Z
P0
I0
P5
5E
T5
T0
W2
8B
8Q
8C