Cables
Recommended parts
Cable
RS-485 signal line
Frame ground wire
Crimping
When connecting one
terminal
wire to one terminal
When connecting two
wires to one terminal
Tools for crimping terminal
Wiring method
1.
Attach crimping terminals on a cable where coating is peeled.
2.
Insert each wire to each connector hole with attention to
the direction of the connector.
3.
Tighten the screws for fixing the connector cable.
Appropriate tightening torque is approx. 0.3 N.m.
When connecting with RS-485 interface of the upper equipment
The upper equipment should be in data reception condition
within 15 ms after data transmission. This control should be
performed for normal operation.
Side face
0.6 mm
4.
Connect the connector to the link unit.
Fit the direction of the connector on the link unit side
and the cable, insert firmly to the end and tighten the
fixing screws.
Uncoupling the connector
Loosen two fixing screws completely and pull
off the connector straight back holding the
protrusion. When it is not pulled off easily,
hold the link unit body and pull it again.
Model
MVVS 2CX0.5SQ
(Cables of AWG22 to 20)
AI0.5-8WH
AI-TWIN2 x 0.5-8WH
CRIMPFOX UD6
Front side
Recommended driver
Manufacturer
OMRON Corporation
3.5 mm
Example of System Configuration
Manufacturer
Tachii Electric Wire Co., Ltd.
PHOENIX CONTACT
Compact slotted screwdriver,
its tip is constant in thickness
Model
XW4Z-00C
Fixing screw
V500-R521B2/C2
Section 5
103
User's Manual