Section 5
Example of System Configuration
Setting at bar code side
Set as follows, using UB command (collective setting for programmable controller
connection).
p.59
Setting item
Communication speed
Data length
Parity
Stop bit
Header
Footer
Reading valid time
Process when reading failed
Setting of CS1 side
For detail setting method, refer to the operation manual of your programmable controller.
Setting item
Dip switch of CPU unit
PC system setting
DM setting
V500-R521B2/C2
90
User's Manual
Setting content
9600 bps
7-bit
Even number
2-bit
None
CR
Trigger + 2 sec.
?[CR] or > [CR] is transferred
Setting content
OFF
160[8300]
161[0000]
164[000D]
165[0100]
Set [1B5A] to DM00100.
(Memorize "Z" of ASCII code)
Command
(Same as initial setting)
L0
L3
L6
(Same as initial setting)
(Same as initial setting)
Y2
5H