Omron V500-R521B2 User Manual page 89

Bar code reader
Table of Contents

Advertisement

Example of program
When the trigger switch is turned on, the bar code reader starts reading operation and stores the
read data to DM (data memory) of CS1. The content is displayed on the programming console.
When the bar code cannot read within the duration which is set beforehand (2 sec. in this
example), "?" or ">" is transmitted.
To check the read data with the programming console, press "Clear > FUN > Monitor" in this
order.
00000
00000
00101
00002
A3920
00006
For the program command, refer to the operation manual of your programming console. (Items
related to communication method by RS-232C nonprocedural system.)
DIFU (13) 00101
TXD (236)
A3920
DM00100
#0000
#0002
BSET (71)
#0000
DM00200
DM00220
RXD(235)
DM00200
#0000
A393
MSG (46)
&0
DM0200
Example of System Configuration
When the contact point 00000 is turned on,
reading start command (Z) is transmitted to the
bar code reader.
When data is received from the bar code reader,
the data is stored starting from the address
DM00200 and displays the content on the
programming console.
V500-R521B2/C2
Section 5