Yamaha F30A Service Manual page 47

Hide thumbs Also See for F30A:
Table of Contents

Advertisement

Item
Fuel control system
Prime Start resistance
at 20 °C (68 °F)
Prime Start plunger length
Starting system
Power bobbin output peak
voltage
(Y/B – Y/B)
at cranking (loaded)
at 1,500 r/min (loaded)
at 3,500 r/min (loaded)
Power bobbin resistance
(Y/B – Y/B)
at 20 °C (68 °F)
Starter motor
Type
Output
Cranking time limit
Brushes
Wear limit
Commutator
Undercut wear limit
Charging system
Fuse
Lighting coil output peak
voltage
at cranking (unloaded)
at 1,500 r/min (unloaded)
at 3,500 r/min (unloaded)
Lighting coil resistance
at 20 °C (68 °F)
Rectifier Regulator output
peak voltage
(R – Ground)
at 1,500 r/min (loaded)
at 3,500 r/min (loaded)
(*1)
The following resistance is when the ambient temperature is 20 °C (68 °F) and there is no power supplied.
The figures are for reference only.
(*2)
The figures are for reference only.
67C3K11
Unit
(*1)
(Y – Y)
(*1)
mm (in)
V
V
V
(*2)
kW
Second
mm (in)
mm (in)
A
(Y – Y)
V
V
V
(*2)
(Y – Y)
V
V
Maintenance specification
Model
F30AEHT
F30AET
20.0–23.0
10.7 (0.42)
7.0
28.0
77.7
6.5–7.2
Bendix
1.20
30
6.4 (0.25)
0.8 (0.03)
20
8.4
28.5
66.6
0.26–0.28
13
13
F40BWHT
F40BET
2-20