Permanent Warnings - Furuno FMD-3200 Operator's Manual

Electronic chart display and information system
Hide thumbs Also See for FMD-3200:
Table of Contents

Advertisement

7. C-MAP CHARTS
Update Date: Date of update
Compilation Scale: The scale of the original paper chart is shown here.
Projection: Projection of current chart.
Horizontal Datum: Horizontal datum used with current chart.
Sounding Datum: Datum used to create sounding data.
Vertical Datum: Vertical datum used with current chart.
Units of Depth: Unit of depth used with current chart.
Units of Height: Unit of measurement used to measure height of objects above sea
level.
Magnetic Variation: Amount of magnetic variation. A positive value indicates a
change in an easterly direction and a negative value indicates a change in a westerly
direction.
Quality Indication: Quantitative estimate of the accuracy of chart features, given by
the chart producer.
7.8

Permanent Warnings

Permanent warnings help you keep the C-MAP up-to-date and these are shown at the
bottom of the screen. Permanent warnings appear if the system detects a condition
that may cause a chart to be not up-to-date.
CMAP: Database not up to date
CMAP: Dynamic license reporting overdue You have not requested an update file for
CMAP: Dynamic licensing credit limit
CMAP: No connection to eToken
CMAP: permits have expired
No connection to dongle.
Not up to date (SSE 27): XXXXXXXX
(Chart name replaces Xs.)
Permit expired (SSE 25): XXXXXXXX
(Chart name replaces Xs.)
7-4
Message
Meaning, Remedy
Database is not up to date. Update the
data base.
more than one week. Get into the Chart
maintenance mode then click the [License]
button. Click the [C-MAP] tab then the [Or-
der Update File] button.
You have exceeded the allotted credit limit.
Raise credit limit.
eToken dongle is not inserted (inside the
Processor Unit) or eToken has not been
initialized. To initialize eToken, open the
[License] dialog box then click the [C-MAP
Setup] and [OK] buttons.
You have an expired permit for a chart. Re-
move the chart or renew subscription for
the permit.
Dongle not inserted. Insert dongle.
At least one chart is not up to date. Load
updated material.
You have an expired permit for a chart. Re-
move the chart or renew subscription for
the permit.