Alarms, Warnings And Cautions - Furuno FE-800 Operator's Manual

Navigational echo sounder
Hide thumbs Also See for FE-800:
Table of Contents

Advertisement

2.8

Alarms, Warnings and Cautions

When an error occurs, the system will attempt to notify the user with an audible alarm and a pop-
up message window, similar to the one shown below.
Press the ALARM ACK key to acknowledge the alert and stop the audible alarm.
There are three priority-based levels to which the alert notification can be assigned. The table
below lists the possible Alarms, Warnings and Cautions in order of priority from most urgent
(Alarms) to least urgent (Cautions).
Note: All notifications are stored in the Alert LOG.
Alert ID
Alert text
230
Depth below Keel
Alarm
201101
TX Volt Error1
201111
TX Volt Error2
201102
RX Volt Error1
201112
RX Volt Error2
201103
TCVR High
Temperature1
201113
TCVR High
Temperature2
201301
DISP COM Error
201302
TCVR COM Error
201001
Bottom Lost
201303
UTC Timeout
201104
Fan0 Speed
Error1
201114
Fan0 Speed
Error2
201950
BAM COM Error
Depending on your Alert mode, Alert ID can be output in two formats, 3-digit or 6 digit.
Alert I/F1 and Legacy alert modes will output alert IDs in 3-digit format. Alert I/F2 will output alerts
in 6-digit format.
Note: "Alert 230: Depth below keel alarm" will only output in 3-digit format.
The 6-digit format has the prefix "201" added to the normal 3-digit format.
For example: Alert ID "201101" is in Alert I/F2 format, the equivalent in Alert I/F1 and Legacy
format is "101".
Note: Alert I/F1, Alert I/F2 and Legacy settings are set during the initial installation. Consult a
FURUNO technician to change these settings.
230 Depth below Keel Alarm
ALARM
Acknowledge
ACK
Priority
Alarm
Warning
Warning
Warning
Warning
Warning
Warning
Warning
Warning
Warning
Caution
Caution
Caution
Caution
Possible Cause
Current depth is less than preset.
Voltage not within safe guidelines on
transceiver 1.
Voltage not within safe guidelines on
transceiver 2.
Voltage not within safe guidelines on
transceiver 1.
Voltage not within safe guidelines on
transceiver 2.
Temperature exceeds safe guidelines on
transceiver 1.
Temperature exceeds safe guidelines on
transceiver 2.
Communication error between display unit
and transceiver 1.
Communication error between transceiver 1
and transceiver 2.
Seabed is not detected by equipment
Connection with EPFS device (GPS) lost.
Fan No.0's speed lower than minimum
speed on transceiver 1.
Fan No 0's speed lower than minimum
speed on transceiver 2.
Communication error with BAM.