Gas Valve Solenoids
All three solenoids are permanently fixed to the valve cover
plate.
Remove the electrical connections, having noted their
positions. The wires are colour coded to each solenoid.
Remove the screws holding the plate to the valve body.
Remove the plate and gasket carefully to avoid losing the
three valves and springs.
Always fit a new gasket.
Reassemble in reverse order of dismantling.
Domestic Hot Water Heat Exchanger
Hinge down the electrical box.
Undo the screws holding the heat exchanger to the
manifolds.
Draw the heat exchanger carefully over the manifolds,
ensuring no wires are caught or damaged.
Remove and inspect the four lip seals, replace if necessary.
Replace in reverse order of dismantling, and re-commission,
ensuring that the off set location peg on the heat exchanger
is to the right.
Baxi Heating Ltd.