Gas Valve Solenoids; Domestic Hot Water Heat Exchanger - Baxi Genesis 80 Installation And Servicing Instructions

Gas fired wall mounted combination boiler
Table of Contents

Advertisement

Genesis
CHANGING COMPONENTS – Page 29
Supplied By www.heating spares.co Tel. 0161 620 6677

Gas Valve Solenoids

All three solenoids are permanently fixed to the valve cover
plate.
Remove the electrical connections, having noted their
positions. The wires are colour coded to each solenoid.
Remove the screws holding the plate to the valve body.
Remove the plate and gasket carefully to avoid losing the
three valves and springs.
Always fit a new gasket.
Reassemble in reverse order of dismantling.

Domestic Hot Water Heat Exchanger

Hinge down the electrical box.
Undo the screws holding the heat exchanger to the
manifolds.
Draw the heat exchanger carefully over the manifolds,
ensuring no wires are caught or damaged.
Remove and inspect the four lip seals, replace if necessary.
Replace in reverse order of dismantling, and re-commission,
ensuring that the off set location peg on the heat exchanger
is to the right.
Baxi Heating Ltd.
29

Advertisement

Table of Contents
loading

This manual is also suitable for:

Genesis 96

Table of Contents