Genesis
Servicing The Appliance – Page 27
Supplied By www.heating spares.co Tel. 0161 620 6677
Annual Servicing
For reasons of safety and economy, it is recommended that
the appliance is serviced annually.
To measure the Co% and (Co
products, remove the LH sample screw and insert a suitable
sampling probe.
Ensure that the appliance is cool.
Ensure that both the gas and electrical supplies to the
appliance are isolated.
Remove the outer case and lower door panel
(See Installation, p18).
Remove the screws securing the door panel.
Remove the door by lifting its lower edge forwards and
upwards, and disengage the lugs on the top corners.
Remove the screws securing the combustion box door.
Remove the door by lifting the lower edge forwards and
upwards through 90º.
Draw the door forwards.
Remove the two screws securing the injector manifold to gas
inlet pipe.
Remove the remaining four screws securing the manifold to
the burner.
Brush any deposits from the injectors. Do not use a pin or
wire to clean them.
Carefully brush the heat exchanger fins.
Brush the burner blades and venturis and combustion box
clean.
Reassemble in reverse order of dismantling and
recommission.
Baxi Heating Ltd.
% content of the flue
2
27