lnjector Manifold
Remove the combustion box door.
Remove the six screws holding the manifold to the burner
and inlet pipe.
Remove the burner flange and draw the manifold forwards.
Reassemble in reverse order.
3 - Way Valve
Close central heating isolating valves and drain down.
Release union nut and remove 'R' clip on central heating
outlet pipe.
Pull forward to disengage pipe spigot.
Remove 'R' clip securing the by pass pipe to the valve.
Pull out the spring clip and unplug the thermistor and
electrical connection.
Remove the clip securing the flow pipe to the heat
exchanger and the 'R' clip holding it to the valve.
Disengage the flow pipe at the heat exchanger end by
easing down, so that the lower end of the pipe slides further
into the valve spigot
Pull pipe upwards to disengage from valve spigot.
Rotate the front end of the valve upwards by ¼ turn to
disengage the bayonet fitting.
Ease the assembly to the left to separate the spigot from the
manifold.
Bring the valve assembly forward and unplug the electrical
connection.
Reassemble in reverse order ensuring all 'O' rings are on the
spigots before assembly.