Fitting The Flue - Baxi Genesis 80 Installation And Servicing Instructions

Gas fired wall mounted combination boiler
Table of Contents

Advertisement

Genesis
Fitting The Flue – Page 20
44 - 45
Supplied By www.heating spares.co Tel. 0161 620 6677
HORIZONTAL FLUE
The standard flue supplied with the appliance is suitable for
lengths 220mm minimum to 610mm maximum.
Rear flue: maximum wall thickness - 490mm.
Side flue,
(left or right): maximum wall thickness - 477mm.
If fitting the optional Intel fitting kit, flue extension kit or
elbows refer to the instructions provided with the kits.
Place the flue elbow on to the flue connection, with the
outlets facing the wall opening.
Measure the distance from the outside wall face to the
elbow. This is to be dimension (X)
Mark dimension (X) on the plastic air duct measuring from
the flue terminal as shown.
Measure the length of waste material from the air duct.
Take the aluminium flue duct and mark off this length. from
the plain end. Do not cut the flared end.
The required dimension of the flue duct is (X)+55mm.
IMPORTANT:
Check your measurements before cutting.
Cut the ducts to size.