Genesis
CHANGING COMPONENTS – Page 37
Supplied By www.heating spares.co Tel. 0161 620 6677
Pressure Relief Valve
Close all water valves and drain as necessary.
Disconnect the union between the valve and the discharge
pipe. -
Slacken the grub screw retaining the valve.
Pull the valve sideways to disengage it.
Reassemble in reverse order.
Pressure Gauge
Hinge down the electrical box.
Remove the spring fork clip retaining the gauge to the facia,
and withdraw the gauge.
Remove the clip retaining the capillary to the manifold.
Reassemble in reverse order.
Flow Switches
The procedure for changing both flow switches is the same
They are interchangeable.
Remove the electrical connection.
Unscrew the switch cap assembly, and remove the "O' ring.
The cap is hand tight so no tool is necessary.
Reassemble in reverse order.
Baxi Heating Ltd.
37