Calibrating The Gas Valve - Baxi 24 Combi Installation And Service Manual

High-efficiency wall-hung condensing gas boiler
Hide thumbs Also See for 24 Combi:
Table of Contents

Advertisement

7 Commissioning
Fig.51
Gas valve
7.4.4

Calibrating the gas valve

V
Gas flow rate setting screw - 4 mm Allen key
OFFSET setting screw - Torx 40 (T40)
K
Remove the boiler door to take measurements or make adjustments.
Calibration of the MAXIMUM heat input
Check that the CO
measured in the exhaust pipe, with the boiler
2
operating at maximum heat input, is as indicated in the table entitled
"Service settings".
If incorrect:
Put the boiler into chimney sweep high mode "H". Let the CO
stabilise.
Important
Remove the Allen key to stabilise the CO
required.
Adjust the setting screw (V) located on the gas valve. Turn the screw
clockwise to increase the content of CO
it.
* Values for G20 gas type only. For G20+20%H2 calibration of the
gas valve refer to O
%.
2
Calibration of the REDUCED heat input
Check that the measurement in the exhaust pipe, with the boiler
operating at minimum heat input, is as indicated in the table entitled
"Service settings".
If incorrect:
Remove the Offset setting screw plug (K) using the Torx driver.
The Offset setting screw is accessible after removing the Offset
setting screw plug (K).
Put the boiler into chimney sweep low mode. Let the CO
stabilise.
Important
Remove the Torx driver to stabilise the CO
adjustment is required.
Adjust the Offset setting screw located on the gas valve. Turn the
screw clockwise to increase the content of CO2 and anti-clockwise
to decrease it.
* Values for G20 gas type only. For G20+20%H2 calibration of the
gas valve refer to O
%.
2
value
2
value if adjustment is
2
and anti-clockwise to decrease
2
8.8 to 9.4
value
2
value if
2
1 to 8.6
600 Combi 2
51