Baxi Genesis 80 Installation And Servicing Instructions page 21

Gas fired wall mounted combination boiler
Table of Contents

Advertisement

Genesis
Fitting The Flue – Page 21
Supplied By www.heating spares.co Tel. 0161 620 6677
Slide the rubber seal and clip over the air duct.
Engage the flared end of the flue duct onto the flue elbow.
Insert the flue duct into the air duct and engage it in the
terminal.
Slide the rubber sleeve over the joint between the air duct
and elbow.
Align the clip over the rubber seal. For neatness the screws
on the clip flange should be below the air duct if possible,
providing they remain accessible.
Secure the clip.
Place the flue gasket on the boiler flue connection.
Slide the flue ducts through the hole in the wall.
Engage the elbow flange and collar on to the flue connection
on top of the boiler. Align the cut-out in the collar with the
two sampling points. Secure with the four screws.
Make good between the wall and air duct outside the
building.
Fit the circular flue trim outside if required. Fit a terminal
guard if necessary (see page 16).
VERTICAL FLUE
Only a flue approved with the Baxi Genesis can be used.
For information on vertical flues consult the Genesis Installer
Guide or Notes for Guidance supplied with the vertical flue
pack.
Baxi Heating Ltd.
21

Advertisement

Table of Contents
loading

This manual is also suitable for:

Genesis 96

Table of Contents