5.4.7 Management Server Settings
Description
Value Range
Default Value
CON_REQ_USER_ID
Value Format
Description
Value Range
Default Value
CON_REQ_PASS
Value Format
Description
Value Range
Default Value
ANNEX_G_STUN_ENABLE
Value Format
262
Administrator Guide
Specifies the time (UTC) to determine when the CPE will initiate the
periodic Inform method calls.
Note
Each Inform call must occur at this reference time plus or minus
an integer multiple of the "PERIODIC_INFORM_INTERVAL".
This "PERIODIC_INFORM_TIME" parameter is used only to set
the "phase" of the periodic Informs. The actual value can be
arbitrarily set far into the past or future.
For example, if "PERIODIC_INFORM_INTERVAL" is set to
86400 (one day) and if "PERIODIC_INFORM_TIME" is set to
midnight on a certain day, then periodic Informs will occur every
day at midnight, starting from the set date.
If the time is set to "unknown time", the start time depends on
the CPE's settings. However, the
"PERIODIC_INFORM_INTERVAL" must still be adhered to.
If absolute time is not available to the CPE, its periodic Inform
behavior must be the same as if the
"PERIODIC_INFORM_TIME" parameter was set to the
"unknown time".
Time zones other than UTC are not supported.
4–32 characters
0001-01-01T00:00:00Z (unknown time)
String
Specifies the username used to authenticate an ACS making a
Connection Request to the CPE.
Max. 63 characters (except ", &, ', :, <, >, and space)
Empty string
String
Specifies the password used to authenticate an ACS making a
Connection Request to the CPE.
Max. 63 characters (except ", &, ', :, <, >, and space)
Empty string
Boolean
Document Version 2015-01