5.4.7 Management Server Settings
Description
Value Range
Default Value
CON_REQ_USER_ID
Value Format
Description
Value Range
Default Value
CON_REQ_PASS
Value Format
Description
Value Range
Default Value
ANNEX_G_STUN_ENABLE
Value Format
262
Administrator Guide
Specifies the time (UTC) to determine when the CPE will initiate the
periodic Inform method calls.
Note
•
Each Inform call must occur at this reference time plus or minus
an integer multiple of the "PERIODIC_INFORM_INTERVAL".
This "PERIODIC_INFORM_TIME" parameter is used only to set
the "phase" of the periodic Informs. The actual value can be
arbitrarily set far into the past or future.
For example, if "PERIODIC_INFORM_INTERVAL" is set to
86400 (one day) and if "PERIODIC_INFORM_TIME" is set to
midnight on a certain day, then periodic Informs will occur every
day at midnight, starting from the set date.
•
If the time is set to "unknown time", the start time depends on
the CPE's settings. However, the
"PERIODIC_INFORM_INTERVAL" must still be adhered to.
If absolute time is not available to the CPE, its periodic Inform
behavior must be the same as if the
"PERIODIC_INFORM_TIME" parameter was set to the
"unknown time".
•
Time zones other than UTC are not supported.
4–32 characters
0001-01-01T00:00:00Z (unknown time)
String
Specifies the username used to authenticate an ACS making a
Connection Request to the CPE.
Max. 63 characters (except ", &, ', :, <, >, and space)
Empty string
String
Specifies the password used to authenticate an ACS making a
Connection Request to the CPE.
Max. 63 characters (except ", &, ', :, <, >, and space)
Empty string
Boolean