Fault codes
(cont.)
Fault
Const.
weath.-
code
comp.
on the
display
FE
X
X
FF
X
X

Repairs

Checking the outside temperature sensor (weather-compen-
sated control unit)
System char-
Cause
acteristics
Burner
Boiler coding
blocked or in a
card or main
fault state
PCB faulty
Burner
Internal fault
blocked or in a
or "E
fault state
RESET" key
blocked
1. Pull plug "X3" from the control unit.
Troubleshooting
Measures
Press "E
RESET". Replace
boiler coding card
or control unit if
the fault persists
Start the equip-
ment again. Re-
place the control
unit if the equip-
ment will not re-
start.