Troubleshooting
Fault codes
(cont.)
Fault
Const.
weath.-
code
comp.
on the
display
EA
X
X
Eb
X
X
EC
X
X
Ed
X
X
F0
X
X
F1
X
X
84
System char-
Cause
acteristics
Burner in a
The ionisa-
fault state
tion current
lies outside
the permissi-
ble range
during cali-
bration
Burner in a
Heat draw-
fault state
off repeat-
edly too low
during cali-
bration
Burner in a
The ionisa-
fault state
tion current
lies outside
the permissi-
ble range
during cali-
bration
Burner in a
Internal fault
fault state
Burner
Internal fault
blocked
Burner in a
Flue gas
fault state
temperature
limiter has
responded.
Measures
Check the ionisa-
tion electrode and
cable.
Press "E
RESET".
Initiate heat draw-
off and trigger
manual calibra-
tion (see page 97)
Press "E
RESET".
Check the ionisa-
tion electrode and
cable.
Press "E
RESET".
Replace the con-
trol unit.
Replace the con-
trol unit.
Check the heating
system fill level.
Vent the system.
Press "E
RESET" after the
flue gas system
has cooled down.