Viessmann Vitodens 333-F Service Instructions Manual page 79

Compact gas fired condensing boiler 3.8 to 26 kw natural gas and lpg version
Hide thumbs Also See for Vitodens 333-F:
Table of Contents

Advertisement

Fault codes
(cont.)
Fault
Const.
weath.-
code
comp.
on the
display
59
X
X
A2
X
A4
X
A7
X
A8
X
System char-
Cause
acteristics
No DHW heat-
Outlet tem-
ing
perature
sensor lead
broken
Emergency
System
mode with in-
pressure too
sufficient sys-
low
tem pressure,
triggered by
code "0d" (see
page 49)
Control mode
Max. system
pressure ex-
ceeded
Control mode
Faulty pro-
as per deliv-
gramming
ered condition
unit
Burner
Air lock in
blocked. The
the internal
venting pro-
circulation
gram is started
pump or
automatically
minimum
(see page 46)
flow rate not
achieved
Troubleshooting
Measures
Check sensors
(see page 89)
Top up with water
Check system
pressure.
Check the func-
tion and sizing of
the diaphragm ex-
pansion vessel.
Vent the heating
system.
Code "0E" is set
to 1 to document
the fault. After the
fault has been re-
moved, reset
manually to 0.
Replace program-
ming unit
Vent the system if
the fault message
continues to be
displayed
79