Fault codes
(cont.)
Fault
Const.
weath.-
code
comp.
on the
display
bC
X
bd
X
bE
X
bF
X
C5
X
X
C6
X
System char-
Cause
acteristics
Control mode
Communica-
tion fault –
without remote
control
Vitotrol re-
mote control,
heating cir-
cuit A1
Control mode
Communica-
without remote
tion fault,
control
Vitotrol re-
mote control,
heating cir-
cuit M2
Control mode
Vitotrol re-
mote control
incorrectly
programmed
Control mode
Incorrect
LON com-
munication
module
Control mode,
Communica-
max. pump
tion fault,
speed
variable
speed inter-
nal pump
Control mode,
Communica-
tion fault –
max. pump
speed
external vari-
able speed
heating cir-
cuit pump,
heating
circuit M2
Troubleshooting
Measures
Check connec-
tions, cable, cod-
ing address "A0"
and remote con-
trol DIP switches
(see page 114).
Check connec-
tions, cable, cod-
ing address "A0"
and remote con-
trol DIP switches
(see page 114).
Check remote
control DIP switch
setting (see
page 114)
Replace the LON
communication
module
Check the setting
of coding address
"30"
Check setting of
coding address
"E5"
81