Specification - Viessmann Vitodens 333-F Service Instructions Manual

Compact gas fired condensing boiler 3.8 to 26 kw natural gas and lpg version
Hide thumbs Also See for Vitodens 333-F:
Table of Contents

Advertisement

Specification

Specification
Rated voltage
Rated frequency
Rated current
Protection class
Protection
Permissible ambient temperature
&
during operation
&
during storage
and transport
Gas fired boilers
Rated output range
T
/T
50/30 °C
V
R
Rated thermal load
range
for central heating
for DHW heating
Connection values
in relation to the max.
load
Natural gas E
Natural gas LL
LPG
Product ID
Note
The supply values are only for documentation purposes (e.g. in the gas contract
application) or to estimate the supplementary volumetric settings. Because of
factory settings, the gas pressure must not be altered from these settings.
Reference: 15 °C, 1013 mbar.
130
230 V
Electronic tempera-
50 Hz
ture limiter setting
6 A
Temperature limiter
I
setting
IP X 4 D to
Line fuse (mains)
EN 60529
Power consumption 160 W
0 to +40 °C
-20 to +65 °C
kW
3.8 to 13
kW
3.6 to 12.3
kW
3.6 to 16.7
3
m
/h
1.77
3
m
/h
2.05
kg/h
1.31
_-0085 BR 0433
82 °C
100 °C (fixed)
max. 16 A–
3.8 to 19
5.2 to 26
3.6 to 17.9
4.9 to 24.7
3.6 to 17.9
4.9 to 24.7
1.89
2.20
1.40
2.61
3.04
1.93

Hide quick links: