Led: Power, Access, Status - Contec IPC-BX800-DC400 User Manual

Ipc series box-pc
Table of Contents

Advertisement

Time from Low Temperature State to BIOS Activation
1
2
3
4 (Min.)
0
-5
-10
-15
-20
(°C)
Figure 5.3. Graph of Time from Low Temperature State to BIOS Activation
CAUTION
This graph is a standard and no one to guarantee the BIOS start time.

LED: POWER, ACCESS, STATUS

There are three LED in the front of this board.
Table 5.3. Display Contents of LED
LED name
POWER LED
OFF
ON (Green)
ACCESS LED
ON (Green)
STATUS LED
OFF
Flashing (green) in
a cycle of 2 - 0.3
second
Flashing in a cycle
of 4 seconds
(green)
ON (Green)
*1 As the heater may be damaged, contact your retailer.
IPC-BX800 Series User's Manual
State
Indicates that this product is switched off.
Indicates that this product is switched on.
Indicates that the IDE device is being accessed.
Indicates that internal heater is switched off.
Indicates that internal heater is switched on.
The flashing cycle gradually changes according to the internal
temperature, which allows the user to find an approximate internal
temperature.
When the internal temperature is about -20°C, the cycle is 2 seconds.
When the temperature is about 0°C, the cycle is 0.3 second.
Indicates that the voltage of the DC power input is abnormal
(a voltage value outside the specified range).
Indicates that an abnormality has occurred in the internal heater. *1