Configuring SNMPv1 and SNMPv2c settings

Step
1.
Enter system view.
2.
Enable SNMP agent.
3.
Create or update MIB view information.
4.
Configure
SNMP
NMS
access
right.
Configure an
Directly
SNMP
community.
Configure an
SNMP group.
Indirectly
Add a user to
the SNMP
group.
Command
system-view
snmp-agent
snmp-agent mib-view
{ excluded | included }
view-name oid-tree [ mask
mask-value ]
snmp-agent community
{ read | write }
community-name [ acl
acl-number | mib-view
view-name ]*
snmp-agent group { v1 |
v2c } group-name
[ read-view read-view ]
[ write-view write-view ]
[ notify-view notify-view ]
[ acl acl-number ]
snmp-agent usm-user { v1 |
v2c } user-name group-name
[ acl acl-number ]