HP 5800 Series Configuration Manual page 175

Hide thumbs Also See for 5800 Series:
Table of Contents

Advertisement

If the temperature reaches the alarming threshold, the device not only repeatedly outputs the log
information and trap information in the terminal display, but also alerts users through the LED on the
device panel.
To configure temperature alarm thresholds for a member device:
Step
1.
Enter system view.
2.
Configure temperature
alarm thresholds for a
member device.
Table 3 Temperature alarm thresholds for a device
Device
5820X-14XG-SFP+ Switch with 2 Interface Slots(JC106A)/
5820X-14XG-SFP+ TAA Switch with 2 Interface Slots(JG259A)
5820X-24XG-SFP+ Switch(JC102A)/
5820X-24XG-SFP+ TAA-compliant Switch (JG243A)
5820AF-24XG Switch(JG219A)
5800-48G-PoE+ Switch with 2 Interface Slots(JC101A)/
5800-48G-PoE+ TAA Switch with 2 Interface Slots(JG242A)
5800-48G-PoE+ Switch with 1 Interface Slot(JC104A)/
5800-48G-PoE+ TAA Switch with 1 Interface Slot(JG257A)
5800-48G Switch with 1 Interface Slot(JC105A)/
5800-48G TAA Switch with 1 Interface Slot(JG258A)
5800-24G-PoE+ Switch(JC099A)/
5800-24G-PoE+TAA Switch(JG254A)
5800-24G Switch(JC100A)/
5800-24G TAA Switch(JG255A)
5800-24G-SFP Switch with 1 Interface Slot(JC103A)/
5800-24G-SFP TAA Switch with 1 Interface Slot(JG256A)
Command
system-view
temperature-limit slot
slot-number hotspot
sensor- number lowerlimit
warninglimit [ alarmlimit ]
168
Remarks
Optional.
By default, the temperature alarm thresholds
follow the specifications listed in
The warning and alarming thresholds must be
higher than the lower temperature limit.
The alarming threshold must be higher than
the warning threshold.
Lower
Warning
Sensor
limit
limit
1
5
70
2
10
90
1
10
80
1
0
67
4
0
61
1
5
70
2
-10
125
3
10
90
1
10
65
2
-10
125
1
10
70
1
5
70
2
-10
125
1
5
70
1
5
65
Table
2.
Alarm
limit
80
100
87
72
66
80
135
100
75
135
80
80
135
80
75

Hide quick links:

Advertisement

Table of Contents
loading

This manual is also suitable for:

5820x seriesA5820x seriesA5800 series