HELP20
Anti-diffusion agent (A-20): J-6082-611-A
1.
Apply the anti-diffusion agent (A-20) to the indicated portion of focus ring.
2.
Aligning with the right end of cut portion on the top of groove of focus ring, install the focus scale plate.
Affix the polyester tape (black) 10mm cut as instructed to the location shown in figure.
Note: • Install the focus scale plate in the direction marked with characters in the figure.
• Fix the focus scale plate with the polyester tape (black) 10mm not to loose.
Focus Ring
Polyester Tape (Black)
10mm (8x18mm)
SAL1680Z (Vario-Sonnar DT 3.5-4.5/16-80 ZA) (Vario-Sonnar T
Cut portion
Reference position
to winding
Groove
Focus Scale Plate
Apply the
anti-diffusion
agent (A-20)
(All circumference)
20 ±2mm
• Character direction of
focus scale plate
DT 16-80mm F3.5-4.5 ZA)
*