Hitachi RCI-1.0FSN3 Service Manual page 69

Indoor units system free series & complementary systems fsn(h)(2/3/4)(e/m)(i)(-du)
Table of Contents

Advertisement

2 Unit installation
Installation on a concrete wall or a concrete block: fit the mounting
bracket to the wall using anchor bolts, as shown in the figure.
Plug size
RPK-(0.8-1.5)FSN(H)3M
M4-M5
Remove the bottom cover by pressing -1- and -2-.
C A U T I O N
Before lifting the unit, prepare any necessary means (ladders, scaffolding, elevator platform, etc.) and check
that the current safety regulations in the place where the installation is taking place are met.
Check that the lifting work can be carried out without the risk of injuries to you or others in the surrounding
area.
Request the assistance of another person to lift the unit.
Lift the unit carefully.
Hang the indoor unit on the mounting bracket, keeping it vertical. Secure the bottom cover and the mounting bracket with
three screws.
C A U T I O N
Make sure the unit is hanging correctly on the mounting bracket. Otherwise, the bracket could fall.
57
SMGB0077 rev.0 - 01/2013
Q'ty
RPK-(2.0-4.0)FSN3M
4
5
Suspension bracket
Screw
Plug
2

Hide quick links:

Advertisement

Table of Contents
loading

Table of Contents