Hitachi RCI-1.0FSN3 Service Manual page 393

Indoor units system free series & complementary systems fsn(h)(2/3/4)(e/m)(i)(-du)
Table of Contents

Advertisement

10 Servicing
Inlet Air Thermistor
Plastic Band (B)
7 Removing Outlet Air Thermistor
a. Remove the front panel according to the "Removing Front Panel" chapter.
b. Lift the front side of the vertical blade up in the direction of the arrow to remove it.
c. Remove 1 screw fixing the outlet air thermistor cover to remove the cover.
Outlet Air Thermistor
d. After removing the insulation, pull out the rubber bush to remove the outlet air thermistor.
e. Remove the tape fixing the thermistor to remove the thermistor.
f. When attaching the outlet air thermistor, attach it in the reverse procedure.
N O T E
• Take care during the work so that the wiring for the thermistor will not get caught in the cover.
• Make sure that it is 29mm from the upper surface of the thermistor cover to the top of the thermistor.
381
Place the wirings for the thermistors
(for inlet air, gas pipe and freeze protection),
and the expansion valve coil into the electriacal box
from the wiring outlet at the upper side.
(The wiring for the expansion valve coil is not included
when using the unit without expansion valve)
Clamp the wirings for the thermistors
(for inlet air, gas pipe and freeze protection),
and the expansion valve coil with the plastic band.
(The wiring for the expansion valve coil is not included
when using the unit without expansion valve)
Vertical
Blade
SMGB0077 rev.0 - 01/2013
Fix the Inlet air thermistor
with the plastic band so that the
Plastic Band (B)
thermistor wire will not be loosened.
Outlet Air Thermistor
Screw Fixing Cover for
Outlet Air Thermistor
Approx.
29mm
Cover for
Outlet Air Thermistor
10