Problems Related to Scanning Results

Problems Related to Scanning Results
Introduction
Overview of the problems related to Scanning Results.
Problems Related to to Scanning Results
#
Problem
Not whole image
scanned
Stitching problems
– Image sections
misaligned (at
points between the
sensors -overlap-
ping pixels)
One or more thin
vertical lines (in the
direction of paper
feeding) on the
scan result, but not
on the original
drawing.
86
Chapter 10 - Trouble Shooting
Possible cause and solution
Check in your scanning application that your size settings
are either for Auto detection or correspond to the size of the
whole original.
Check in your scanning application that you are loading the
original correctly. Be sure to align the center of the original
with the scanner's center arrow marking.
Remove the original from the scanner and calibrate the
scanner with the Scanner Maintenance program. Calibration
includes correction of stitching errors.
If the problem persists after calibration
– Your sensors may need readjusting. Summon your techni-
cal service provider.
This is often caused by an unclean glass plate. Even a single
spec of dirt in the wrong spot on the glass plate can apply a
streak along your entire scan. To remedy:
Clean your glass plate and rollers as described in this users's
guide.
If the problem persists after cleaning, calibrate the scanner
with the scanner maintenance program. The scanner may
have memorized dirt specs and you need to recalibrate after
dirt-removal.
If the problem persists after cleaning and calibration –Check
the glass plate for scratches. A damaged glass plate should
be replaced. Obtain a new glass plate from your service
provider. Follow the steps in the user's guide to replace the
glass plate with a new one.