Bridge unit right shaft assembly removal

1.
Remove the bridge unit rear cover. See
2.
Remove the bridge unit transport belt and bridge unit drive pulley. See
unit drive pulley removal" on page
3.
Remove the 6 mm bushing (A) from the bridge unit right shaft assembly (B).
4.
Open the bridge unit top cover assembly (C).
5.
Use a prying tool to remove the e-clip securing the 6 mm bushing (D) to the bridge unit assembly.
6.
Remove the 6 mm bushing (D).
7.
Move the bridge unit right shaft assembly (B) toward the right as shown.
8.
Remove the bridge unit right shaft assembly (B) from the two transport belts (E).
9.
Remove the bridge unit right shaft assembly (B).
"Bridge unit rear cover removal" on page
4-8.
C
B
A
E
"Bridge unit drive belt and bridge
Rear
B
D
Front
Repair information