DIAGNOSTICS: SYSTEM TEST – SMART STOP MODE
Upon entry into the test, if the smart stop PCB is not plugged in, a message will be displayed "Smart Stop
Unplugged". This test will allow the user to test the Smart Stop System. If the smart stop system detects a user it
will scroll the profile window from empty to full depending on the percentage of detection that is occurring. Other
smart stop information will scroll automatically every 3 seconds.
The following is a list of the current information that can be seen. If an error has occurred, refer to the
troubleshooting section for corrective action.
ERROR CONDITION
SMART STOP UNPLUGGED
The smart stop system can be turned ON/OFF in this test. When the message "SMART STOP ON" is placed on the
message center, an arrow key will toggle it to "SMART STOP OFF".
The display can be put into a locked mode by pressing the 'PAUSE' key. This will prohibit the scrolling of the smart
stop information.
Pressing the 'CLEAR' key to exit the smart stop test and return to the System Test Menu.
SMART STOP ON
DISPLAYED INFORMATION
SMART STOP ON
SMART STOP OFF
USER DETECTED
USER NOT DETECTED
SMART STOP ADJUST-XX
24