1J-6 Charging System:
12) Remove the generator stator (8).
8
Installation
Install the generator in the reverse order of removal. Pay
attention to the following points:
• Tighten the generator stator set bolts and generator
lead wire set bolt to the specified torque.
NOTE
Be sure the grommet (1) is set to the
generator cover.
Tightening torque
Generator stator set bolt (a): 11 N·m (1.1 kgf-m,
8.0 lb-ft)
Generator lead wire set bolt (b): 6 N·m (0.6 kgf-
m, 4.5 lb-ft)
(a)
• Degrease the tapered portion "A" of generator rotor
and also the crankshaft "B". Use nonflammable
cleaning solvent to wipe off oily or greasy matter and
make these surfaces completely dry.
• Install the generator rotor onto crankshaft.
I837H11A0013-01
• Hold the generator rotor with the special tool and
tighten its bolt to the specified torque.
Special tool
Tightening torque
Generator rotor bolt (c): 120 N·m (12.0 kgf-m, 87.0
lb-ft)
1
• Apply a bond lightly to the mating surfaces at the
parting line between the upper and lower crankcases
(b)
as shown.
No.1207B or equivalent)
I837H11A0014-02
"B"
(A): 09930–44520 (Rotor holder)
(A)
: Sealant 99000–31140 (SUZUKI BOND
"A"
I837H11A0015-02
(c)
I837H11A0016-02
I837H11A0017-01