1J-4 Charging System:
3) Measure the resistance between the three lead
wires.
If the resistance is out of specified value, replace the
stator with a new one. Also, check that the generator
core is insulated properly.
NOTE
When making this test, be sure that the
battery is in fully charged condition.
Special tool
: 09900–25008 (Multi-circuit tester set)
Tester knob indication
Resistance (Ω)
Generator coil resistance
0.2 – 1.0 Ω (Y – Y)
∞ Ω (Y – Ground)
4) Connect the generator coupler.
5) Install the air cleaner box. Refer to "Air Cleaner Box
Removal and Installation in Section 1D (Page 1D-
7)".
No-load Performance
1) Lift the air cleaner box. Refer to "Air Cleaner Box
Removal and Installation in Section 1D (Page 1D-
7)".
2) Disconnect the generator coupler (1).
3) Start the engine and keep it running at 5 000 r/min.
Y
Y
Y
I837H11A0002-01
1
I837H11A0003-01
4) Using the multi-circuit tester, measure the voltage
between three lead wires.
If the tester reads under the specified value, replace
the generator with a new one.
Special tool
: 09900–25008 (Multi-circuit tester set)
Tester knob indication
Voltage (~)
Generator no-load performance (When engine is
cold)
65 V (AC) and more at 5 000 r/min
5) Connect the generator coupler.
6) Install the air cleaner box. Refer to "Air Cleaner Box
Removal and Installation in Section 1D (Page 1D-
7)".

Generator Removal and Installation

Removal
1) Drain engine oil. Refer to "Engine Oil and Filter
Replacement in Section 0B (Page 0B-10)".
2) Lift the air cleaner box. Refer to "Air Cleaner Box
Removal and Installation in Section 1D (Page 1D-
7)".
3) Disconnect the generator coupler (1).
Y
Y
Y
I837H11A0004-01
B838H21A06004
1
I837H11A0005-01