Calibration Page - AMX Modero ViewPoint MVP-5200i Operation/Reference Manual

5.2" modero viewpoint touch panel with intercom
Hide thumbs Also See for Modero ViewPoint MVP-5200i:
Table of Contents

Advertisement

Protected Setup Pages
Certificate files frequently use 5 file extensions. It can be confusing because there is not a one to one
correspondence. The following table shows the possible file extension used for each certificate type:
Certificates and their Extensions
Certificate Type
PEM
DER
PKCS12
Please note which certificate types are supported by the different certificate fields used on the configuration
screens (PEAP, TTLS, and TLS). The following table outlines the firmware fields and their supported
certificate types.
Certificate Types Supported by the Modero Firmware
Configuration Field Name Certificate File Type Supported
Certificate Authority field
Client Certificate field
Private Key field

Calibration Page

The Calibration page (FIG. 70) allows you to calibrate the touch panel for accurate button selection.
FIG. 70
Calibration page
1.
Press and hold the center button on the navigation wheel for 6 seconds to access the Calibration page (see
FIG. 54).
2.
Press the crosshairs in turn. If the crosshairs are not touched within ten seconds, the MVP-5200i will
return to the Protected Setup page.
3.
The page will read "Calibration Successful. Touch to continue." Touch anywhere on the screen to return
to the Protected Setup page.
74
Possible File Extensions
.cer
.pem
.pvk
.cer
.der
.pfx
PEM and DER
PEM and DER
.PEM, DER, and PKCS12
MVP-5200i 5.2" Modero® ViewPoint® Touch Panel with Intercom