Cleaning The Photoconductor Drum; Maintenance Approach; Tools - Lexmark X215 MFP Service Manual

Hide thumbs Also See for X215 MFP:
Table of Contents

Advertisement

Cleaning the photoconductor drum

If there are streaks or spots on your print, the photoconductor drum
may require cleaning. The operator panel menu includes a Clean
Drum option that may help to improve the print quality.
To clean the photoconductor drum:
1. Make sure paper is loaded.
2. Press Menu until MACHINE SETUP appears on the top line of
the display, and then press Select.
3. Press the scroll button
the bottom line of the display, and then press Select.
The machine prints out a cleaning page. Toner particles on the
photoconductor surface are affixed to the paper.
If the problem persists, repeat these steps.
If the photoconductor drum has been cleaned several times and the
problem is still unresolved, install a new toner cartridge.

Maintenance approach

The diagnostic information in this manual leads you to the correct
field replaceable unit (FRU) or part. Use the error messages, and
diagnostic aids to determine the printer problem and repair the
failure. After you complete the repair, perform tests as needed to
verify the repair.

Tools

The removal and adjustment procedures require the following tools
and equipment:
Analog or digital multimeter
Pliers: diagonal and needle-nose
Screwdrivers: #1 and #2 Phillips
Cotton swab
When you make voltage readings, always use frame ground unless
another ground is specified.
or
until CLEAN DRUM appears on
General information
4038-001
1-9

Hide quick links: