Error 0X - Sony CBK-HD01 Maintenance Manual

Professional disc camcorder; hd/sd sdi input board; analog composite input board
Table of Contents

Advertisement

3-2-2. Error 0X

When errors related to optical drive control or to devices are detected, the following error codes are
displayed.
Main
Sub
Time data
code
code
display
02
020
F2E
F37
X25
X26
X27
X28
X37
03
060
X54
X57
X58
X67
X68
04
X7C
X7D
06
049
E41
F41
08
091
095
292
992
* : The vertical move of loading/unloading is also carried out by STBY ON/OFF.
PDW-700/V1 (E)
Maintenance
Drive
Description
logger
logger
O
O
Optical block assembly is recording at maximum laser output.
Perform the pickup lens cleaning. (Refer to Section 4-10-17.)
O
O
Laser of optical block assembly is determined to be deteriorated in the laser
deterioration assessment for optical block assembly.
O
O
No movement is detected in the ND filter initial operation check of optical
block assembly.
O
O
The laser output of the optical block assembly is abnormal.
O
O
The laser output coefficient of the optical block assembly cannot be adjusted.
O
O
The laser current of the optical block assembly is abnormal (zero or
excessive).
O
O
The optical block assembly laser output is stopped due to the judgment that
no cartridge is inserted.
O
O
The ND filter setting of the optical block assembly cannot be changed.
X
O
Tracking servo of optical block assembly is frequently down.
O
O
No signal can be detected from the disc required for the focus servo of the
optical block assembly.
O
O
No control current is detected in the focus servo of the optical block
assembly.
O
O
Excessive control current is detected in the focus servo of the optical block
assembly.
O
O
No control current is detected in the tracking servo of the optical block
assembly.
O
O
Excessive control current is detected in the tracking servo of the optical block
assembly.
O
O
Optical block assembly cannot move to disc's innermost circumference.
O
O
Optical block assembly cannot move to disc's outermost circumference.
O
O
SA actuator of optical block assembly cannot move to the target position.
O
O
The SA actuator reference position cannot be detected during the startup
adjustment of the optical block assembly.
O
O
The SA actuator reference position cannot be detected during the power-on
initialization of the optical block assembly.
O
O
Spindle motor does not rotate after the predetermined time has passed (or no
FG signal is detected).
O
O
Spindle motor cannot be stopped (or abnormal FG signal is detected).
O
O
Spindle motor rotation is detected during vertical move of loading.
O
O
Spindle motor rotation is detected during vertical move of unloading.
*
*
3-3