3-2-2. Error 0X
When errors related to optical drive control or to devices are detected, the following error codes are
displayed.
Main
Sub
Time data
code
code
display
←
02
020
←
F2E
←
F37
←
X25
←
X26
←
X27
←
X28
←
X37
←
03
060
←
X54
←
X57
←
X58
←
X67
←
X68
←
04
X7C
←
X7D
←
06
049
←
E41
←
F41
←
08
091
←
095
←
292
←
992
* : The vertical move of loading/unloading is also carried out by STBY ON/OFF.
PDW-700/V1 (E)
Maintenance
Drive
Description
logger
logger
O
O
Optical block assembly is recording at maximum laser output.
Perform the pickup lens cleaning. (Refer to Section 4-10-17.)
O
O
Laser of optical block assembly is determined to be deteriorated in the laser
deterioration assessment for optical block assembly.
O
O
No movement is detected in the ND filter initial operation check of optical
block assembly.
O
O
The laser output of the optical block assembly is abnormal.
O
O
The laser output coefficient of the optical block assembly cannot be adjusted.
O
O
The laser current of the optical block assembly is abnormal (zero or
excessive).
O
O
The optical block assembly laser output is stopped due to the judgment that
no cartridge is inserted.
O
O
The ND filter setting of the optical block assembly cannot be changed.
X
O
Tracking servo of optical block assembly is frequently down.
O
O
No signal can be detected from the disc required for the focus servo of the
optical block assembly.
O
O
No control current is detected in the focus servo of the optical block
assembly.
O
O
Excessive control current is detected in the focus servo of the optical block
assembly.
O
O
No control current is detected in the tracking servo of the optical block
assembly.
O
O
Excessive control current is detected in the tracking servo of the optical block
assembly.
O
O
Optical block assembly cannot move to disc's innermost circumference.
O
O
Optical block assembly cannot move to disc's outermost circumference.
O
O
SA actuator of optical block assembly cannot move to the target position.
O
O
The SA actuator reference position cannot be detected during the startup
adjustment of the optical block assembly.
O
O
The SA actuator reference position cannot be detected during the power-on
initialization of the optical block assembly.
O
O
Spindle motor does not rotate after the predetermined time has passed (or no
FG signal is detected).
O
O
Spindle motor cannot be stopped (or abnormal FG signal is detected).
O
O
Spindle motor rotation is detected during vertical move of loading.
O
O
Spindle motor rotation is detected during vertical move of unloading.
*
*
3-3