7.3.4 Defective CPU Disconnection Function

This server is equipped with the defective CPU disconnection function.
This function disconnects the CPU judged to be defective (abnormal) during Power On Self Test
(POST) to start the server. On two CPU servers, if one CPU is defective, the other CPU starts up the
server.
The failed CPU can be checked using the information displayed during POST or from [CPUn Status] (n:
slot number) in the [CPU Status] submenu of the [Server] menu in the BIOS Setup Utility ( "8.2.10
CPU Status Submenu" (p.183)).
■ Replacing the defective CPU
Replace the defective CPU with a new one according to "7.3.3 How to Install a CPU" ( p.142).
After replacing the CPU, start the BIOS Setup Utility and select the [Server] menu - the [CPU Status]
submenu to check that [CPU n Status] (n is the number of the replaced CPU) is set to [Enabled]. If the
item is set to [Disabled], change the setting to [Enabled]. If the item is set to [Disabled] or [Failed],
change the setting to [Enabled]. If it is not set to [Enabled], the server will start with the CPU
recognized as being defective and constantly disconnected.
To use the new CPU, set the item to [Enabled] for releasing the failed CPU status at the next startup.
"8.2.10 CPU Status Submenu" (p.183)
PRIMERGY BX620 S4 Server Blade User's Guide