Adjustment
11
Limiting the stitch length
.05.09
11 - 11
Requirement
1. When the reverse feed switch is fully pressed, the stitch length must be 1.5 mm.
2. When the maximum stitch length is set, the feed dog must not come into contact with
the needle plate cutout.
2
1
Fig. 11 - 10
Set stitch length at 1.5 mm.
Turn screw 1 (nut 2) according to requirement 1.
Adjust stop 3 (screw 4) according to requirement 2.
3
4
1.5 mm.
1.5 mm.
1.5 mm.
1.5 mm.