Combustion Fan Replacement - Regency IP28-NG Owners & Installation Manual

Gas inbuilt
Hide thumbs Also See for IP28-NG:
Table of Contents

Advertisement

Before you start:
Ensure all power is turned off.
1) Turn the unit off and allow it to cool to room temperature,
2) Unplug or disconnect power source to stove.
3) Open the bottom louvre.
4) Remove convection fan - see previous page.
5) Remove 4 screws to release fan.
6) Disconnect polarized plug.
7) Disconnect tubing from right side of fan.
8) Disconnect ground wire.
Regency IP28 Gas Inbuilt Fireplace

COMBUSTION FAN REPLACEMENT

Tubing
8) Manoeuvre fan from base of unit and replace.
9) Reverse steps to reinstall.
MAINTENANCE