MASONARY MINIMUM
FIREPLACE OPENING
DIMENSIONS
(CONTEMPORARY FASCIA)
The minimum fi replace dimensions for the
Regency gas space heater when using the
Contemporary Fascia are shown in the follow-
ing diagrams:
NOTE: ALLOW FOR SIDE GAS CONNEC-
TION - IF REQUIRED
27-1/2" (699mm)
27-1/2" (699mm)
15-1/8" (384mm)
(SLIM LINE FASCIA)
The minimum fi replace dimensions for the Regency
gas space heater when using the Slim line Fascia
are shown in the following diagrams:
NOTE: ALLOW FOR SIDE GAS CONNECTION
- IF REQUIRED
27-1/2" (699mm)
28-7/8" (735mm)
17" (432mm)
Regency IP28 Gas Inbuilt Fireplace
COMBUSTIBLE
"MOCK FIREPLACE"
MINIMUM FIREPLACE
OPENING DIMENSIONS
The minimum fi replace dimensions for the
Regency gas space heater when installing into
a combustible mock fi replace are shown in the
following diagrams:
(For Contemporary Fascia)
770mm
770mm
490mm
(For Slim line Fascia)
770mm
770mm
490mm
INSTALLATION
CLEARANCES TO
COMBUSTIBLES
Minimum Clearances to Combustibles
From Unit
Sides
A
2" / 51mm
Ceiling
B
39-3/8" / 1000mm
Mantel
C
Max. Mantle Depth
E
12" / 305mm
(see Dia. 2)
Min. Alcove Width
F
44-7/8" / 1139 mm
Max. Alcove Depth
G
36" / 914 mm
*No hearth required.
Mantel Clearances
12
10
8
6
4
20
12" Mantel
(305mm)
18
16
14
3-1/2" (89mm)
Mantel
12
10
20" (508mm)
8
6
11" (279mm)
4
2
0
11" / 279mm
2
Top
Faceplate
9