Aeration Settings - Regency IP28-NG Owners & Installation Manual

Gas inbuilt
Hide thumbs Also See for IP28-NG:
Table of Contents

Advertisement

The burner aeration is factory set but may need adjusting due to either the local gas supply, air supply or altitude. This adjustment is performed by the installer.
(Close the aeration for a more yellow fl ame, or open it to make the fl ame bluer).
NG:
7.94mm open
LPG
15mm open
Note: Any damage due to carboning resulting from improperly setting the aeration is NOT covered under warranty.
Regency IP28 Gas Inbuilt Fireplace
System Data
IP28
Burner Inlet Orifi ce Sizes:
NG
Propane
Burner
#39
#53
Max. Input
NG
28.8 mj
Propane
28.8 mj
Supply Pressure
NG
1.13 kPa
Propane
2.75 kPa
Manifold Pressure
HIGH
NG
0.88 kPa
Propane
2.49 kPa
Electrical: 240 V. 50Hz.
Circulation: High/LO speed fan,
Log Set: Ceramic fi bre, 4 per set.
Aeration Setting
NG
7.94mm open
Propane 15mm open

AERATION SETTINGS

INSTALLATION
LOW
0.4kPa
1.6kPa
15